Shielded and unshielded power, control and signal transmission cable with supporting element for crane facilities, current entries to high rack transport vehicles, in industrial television on moving cameras and machine tools. Applicable for all control, measure and telecommunication systems. Suitable for dry and humid rooms.
•conform to RoHS •conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | Bare copper strand |
---|---|
Conductor class: | Acc. to DIN VDE 0295 class 5/6 resp. IEC 60228 class 5/6 |
Core insulation: | PVC |
Core identification: | Acc. to VDE 0293-308 up to 5 wires coloured, from 6 wires black with white numerals with or without GNYE resp. special colour |
Stranding: | Cores resp. bundles parallel side by side |
Shield: | Single core or bundle with copper braid or wrapped wire bare or tinned; coverage ca. 70% - 80% |
Outer sheath: | PVC |
Sheath colour: | Black, RAL 9005 |
Rated voltage: | 0,5 mm² = 300V; > 1,0 mm² = Uo/U 300/500 V |
Testing voltage: | 1,2 kV / 2 kV |
Current-carrying-capacity: | Acc. to DIN VDE, see Technical Guideline |
Min. bending radius fixed: | 10 x d |
Min. bending radius moved: | 10 x d |
Operat. temp. fixed min/max: | H05...: -25 °C / +60 °C; KY...: -40 °C / +70 °C |
Operat. temp. moved min/max: | H05...: -25 °C / +60 °C; KY...: -25 °C / +60 °C |
Temp. at conductor: | +70 °C |
Burning behavior: | Self-extinguishing and flame retardant acc. to IEC 60332-1 |
Suspension height: | See table |
Standard: | Similar to DIN VDE 0250 |